Data Center 32-Zone High Security System - Multi-Layered Protection
Security System

Data Center 32-Zone High Security System - Multi-Layered Protection

EPC Price Range
$68,000 - $95,000

Key Features

  • 32-zone hybrid alarm panel with 28 advanced detectors including 12 dual-tech sensors for 90% false alarm reduction
  • 20-camera surveillance array: 12x 4K IP (150m IR range), 4x PTZ (20x zoom), 4x thermal (300m+ detection)
  • 24-channel NVR with H.265+ compression, 30-day 4K retention, and AI analytics for intelligent threat detection
  • Multi-factor access control for 8 doors with 2 biometric readers, 4 keypads, and complete audit trail logging
  • Grid-redundant power with 8+ hour UPS backup, AES-256 encrypted dual-path communications, and FM-200 fire suppression

Description

The SOLARTODO Data Center 32-Zone High Security system represents the pinnacle of physical threat detection and access management, engineered specifically for the stringent requirements of modern data centers, government facilities, and other high-value asset environments. This integrated solution provides a multi-layered defense architecture, combining advanced intrusion detection, 24/7 high-definition surveillance, and sophisticated access control to ensure operational integrity and protect against unauthorized access, theft, and environmental hazards. Designed for absolute reliability, the system incorporates grid-redundant power with extensive battery backup, encrypted communications, and full compliance with leading international security standards, including EN 50131 Grade 3 and IEC 62676.

At its core, the system is managed by a powerful 32-zone hybrid control panel, which serves as the central nervous system for all connected devices. This panel supports both wired and wireless configurations, offering installation flexibility while maintaining the highest level of security. The configuration includes 28 high-sensitivity detectors strategically deployed across the facility. This array comprises 12 dual-technology (microwave and PIR) motion sensors that provide exceptional false alarm immunity by cross-verifying detection signals, a critical feature in environments with complex airflow and thermal variations. These are supplemented by 8 magnetic door contacts for securing all entry and exit points, and 8 advanced photoelectric smoke detectors compliant with NFPA 72 for early fire detection.

Visual intelligence is delivered by a formidable array of 20 state-of-the-art cameras, ensuring comprehensive coverage of all critical areas. The system includes 12 4K Ultra HD IP cameras, which provide crystal-clear imaging and feature a powerful infrared (IR) illumination range of up to 150 meters for effective night-time surveillance. For dynamic monitoring of large areas, 4 Pan-Tilt-Zoom (PTZ) cameras with 20x optical zoom allow security operators to closely inspect suspicious activity from a central command center. The surveillance capabilities are further enhanced by 4 high-precision thermal cameras, capable of detecting human presence at distances exceeding 300 meters based on thermal signatures alone, rendering them effective in complete darkness, fog, or smoke.

All video feeds are processed and stored on a 24-channel Network Video Recorder (NVR) equipped with high-capacity RAID storage, ensuring a minimum of 30 days of continuous 4K video retention. The NVR utilizes the highly efficient H.265+ video compression standard, reducing storage and bandwidth requirements by up to 80% compared to older H.264 systems without compromising image quality. Onboard AI video analytics, compliant with IEC 62676-5, provide intelligent event processing, including person and vehicle classification that can reduce false alarms by over 90%. The system can be configured for advanced intrusion detection, line crossing alerts, and object left/removed detection, automating threat identification and enabling a proactive security response.

Controlling physical access is a cornerstone of data center security. This system implements a robust, multi-layered access control solution for up to 8 doors, scalable as needed. It moves beyond simple key cards to enforce multi-factor authentication (MFA) at critical entry points, requiring a combination of a proximity card, a unique PIN entered on one of the 4 included LCD keypads, and biometric verification. The system includes 2 advanced biometric readers that use fingerprint scanning to provide an irrefutable layer of identity verification, adhering to the principles outlined in standards like ISO/IEC 19794.

This layered approach creates a formidable barrier against unauthorized entry. For instance, access from the building exterior to the main data hall can be structured through mantrap or airlock-style entries, where a user must clear one authentication level before proceeding to the next. The system logs every access attempt, providing a complete audit trail for compliance and forensic investigation. In the event of a security breach or duress situation, the system can be configured to trigger a silent alarm to the 24/7 monitoring station while appearing to grant access, a critical feature for protecting personnel and assets.

In a high-security environment, continuous operation is non-negotiable. The Data Center 32-Zone system is designed with a grid-redundant power architecture to guarantee 100% uptime. The primary power is drawn from the main electrical grid, but in the event of an outage, the system seamlessly transitions to a high-capacity Uninterruptible Power Supply (UPS) that can sustain full operation for a minimum of 8 hours. This provides a crucial window for backup generators to activate, ensuring long-term autonomy. The system's power infrastructure is designed in accordance with UL 681 standards for the installation and classification of burglar and holdup alarm systems.

Communication with the central monitoring station is equally resilient. The primary communication path is a hardwired Ethernet connection, offering high speed and reliability. As a failsafe, the system includes a 4G/LTE cellular module that automatically takes over if the primary network connection is lost. All communications between the control panel and the monitoring center are encrypted using the AES-256 standard, one of the most secure encryption protocols available, to prevent interception or jamming. This dual-path, encrypted communication ensures that every system event, from a simple sensor activation to a critical alarm, is transmitted securely and reliably.

Beyond intrusion and access control, the system provides comprehensive life safety and environmental protection. The 8 integrated photoelectric smoke detectors are linked to the main alarm panel and a dedicated fire suppression system. This configuration includes an FM-200 clean agent fire suppression system, which can extinguish a fire in seconds without damaging sensitive electronic equipment or leaving a residue, making it the industry standard for data center environments. Upon detection of smoke, the system can automatically trigger the FM-200 release, activate audible and visual alarms through the 4 included high-decibel sirens with integrated strobes, and alert the monitoring station and emergency services in accordance with NFPA 72 guidelines.

Environmental monitoring can be further expanded to include sensors for temperature, humidity, and water leakage. These sensors can be configured to trigger alerts if conditions deviate from predefined optimal ranges, preventing equipment damage from overheating or water ingress. This proactive approach to environmental control helps maintain the ideal operating conditions for high-value IT assets, minimizing the risk of costly downtime and contributing to the overall resilience of the data center.

Technical Specifications

Security Zones32zones
Camera Count20cameras
Detector Count28detectors
Power SystemGrid Redundant with UPS
Backup Autonomy8hours
Video Storage30 days @ 4K
NVR Channels24channels
Access Control Doors8doors
Biometric Readers2readers
Monitoring TypeFull Service 24/7/365
CommunicationEthernet + 4G/LTE + WiFi
Encryption StandardAES-256
Expansion Capacity64zones
Fire SuppressionFM-200 Clean Agent
Warranty2 years parts, 1 year labor

Price Breakdown

ItemQuantityUnit PriceSubtotal
32-Zone Hybrid Alarm Panel1 pcs$450$450
LCD Keypad with Touchscreen4 pcs$85$340
Dual-Technology Motion Detector12 pcs$65$780
Door/Window Magnetic Contact8 pcs$15$120
Photoelectric Smoke Detector8 pcs$40$320
4K Ultra HD IP Camera (150m IR)12 pcs$150$1,800
PTZ Camera (20x Optical Zoom)4 pcs$450$1,800
Thermal Imaging Camera4 pcs$1,200$4,800
24-Channel NVR with RAID Storage1 pcs$600$600
Biometric Fingerprint Reader2 pcs$280$560
Access Control Magnetic Lock8 pcs$120$960
High-Decibel Siren with Strobe4 pcs$95$380
FM-200 Fire Suppression System1 pcs$8,500$8,500
Grid-Redundant Power Supply with UPS1 pcs$1,800$1,800
4G/LTE Communication Module1 pcs$180$180
Professional Installation (32 zones)32 pcs$50$1,600
24/7 Full-Service Monitoring (12 months)12 pcs$45$540
System Integration and Programming1 pcs$2,500$2,500
Network Cabling and Infrastructure1 pcs$3,200$3,200
Training and Documentation1 pcs$1,200$1,200
Total Price Range$68,000 - $95,000

Frequently Asked Questions

What level of security standard does this system comply with?
The Data Center 32-Zone High Security system is engineered to meet the rigorous requirements of several international standards. It is designed for compliance with EN 50131-1 Grade 3 for intrusion and hold-up systems, which is intended for high-risk commercial environments where intruders are expected to have advanced knowledge and tools. The video surveillance components adhere to the IEC 62676 series for CCTV systems, and the fire detection and suppression elements are aligned with NFPA 72 and UL standards.
How does the system prevent false alarms?
False alarms are minimized through a combination of advanced hardware and intelligent software. The 12 dual-technology detectors require both passive infrared (PIR) and microwave sensors to trigger simultaneously, drastically reducing false positives from environmental factors. Furthermore, the camera system's AI-powered analytics can differentiate between humans, vehicles, and other movements, achieving a false alarm reduction rate of over 90% compared to traditional motion detection, ensuring security teams only respond to genuine threats.
What happens in the event of a power failure?
The system features a robust grid-redundant power design. During a power outage, it instantly switches to an integrated Uninterruptible Power Supply (UPS) that can power the entire security system for at least 8 hours. This provides ample time for the facility's backup generators to come online for extended operation. This multi-tiered power solution ensures that the security of your facility is never compromised, even during prolonged utility disruptions.
Can the system be expanded in the future?
Yes, the system is designed for scalability. The central control panel, while configured for 32 zones, can be expanded to support up to 64 zones with additional expansion modules. Similarly, the NVR has 24 channels but can be networked with other NVRs to support a larger number of cameras. The access control system can also be expanded to manage additional doors and biometric readers, allowing the security infrastructure to grow alongside your facility's needs.
What does the full_service monitoring include?
Full-service monitoring provides 24/7/365 professional oversight from a secure, off-site central command center. Trained operators respond to every alarm event within seconds, verifying the threat by reviewing live camera feeds and system data. They can dispatch law enforcement or emergency services, remotely manage access control, and provide real-time audio communication. This comprehensive service ensures that every alert is handled swiftly and effectively, providing complete peace of mind and a proactive security posture.

Certifications & Standards

EN 50131-1 Grade 3
IEC 62676-5
IEC 62676-5
NFPA 72
UL 681
ISO/IEC 19794
ISO/IEC 19794

Data Sources & References

  • EN 50131 Alarm Systems Standard 2025
  • IEC 62676 Video Surveillance Systems 2024
  • NFPA 72 National Fire Alarm Code 2025
  • UL 681 Installation and Classification of Burglar Alarm Systems

Project Cases

Data Center 32-Zone High Security System - Multi-Layered Protection - 1
Data Center 32-Zone High Security System - Multi-Layered Protection - 2

Interested in this solution?

Contact us for a customized quote based on your specific requirements.

Contact Us
Data Center 32-Zone High Security System - Multi-Layered Protection | SOLAR TODO | SOLARTODO